Source code for azure.servicebus._common.auto_lock_renewer

# ------------------------------------------------------------------------
# Copyright (c) Microsoft Corporation. All rights reserved.
# Licensed under the MIT License. See License.txt in the project root for
# license information.
# -------------------------------------------------------------------------

import datetime
import logging
import threading
import time
from concurrent.futures import ThreadPoolExecutor
from typing import TYPE_CHECKING

from .._servicebus_receiver import ServiceBusReceiver
from .._servicebus_session import ServiceBusSession
from .message import ServiceBusReceivedMessage
from ..exceptions import AutoLockRenewFailed, AutoLockRenewTimeout, ServiceBusError
from .utils import get_renewable_start_time, utc_now, get_renewable_lock_duration

if TYPE_CHECKING:
    from typing import Callable, Union, Optional

    Renewable = Union[ServiceBusSession, ServiceBusReceivedMessage]
    LockRenewFailureCallback = Callable[[Renewable, Optional[Exception]], None]

_log = logging.getLogger(__name__)

SHORT_RENEW_OFFSET = 0.5  # Seconds that if a renew period is longer than lock duration + offset, it's "too long"
SHORT_RENEW_SCALING_FACTOR = (
    0.75  # In this situation we need a "Short renew" and should scale by this factor.
)


[docs]class AutoLockRenewer(object): """Auto renew locks for messages and sessions using a background thread pool. :param max_lock_renewal_duration: A time in seconds that locks registered to this renewer should be maintained for. Default value is 300 (5 minutes). :type max_lock_renewal_duration: float :param on_lock_renew_failure: A callback may be specified to be called when the lock is lost on the renewable that is being registered. Default value is None (no callback). :type on_lock_renew_failure: Optional[LockRenewFailureCallback] :param executor: A user-specified thread pool. This cannot be combined with setting `max_workers`. :type executor: Optional[~concurrent.futures.ThreadPoolExecutor] :param max_workers: Specify the maximum workers in the thread pool. If not specified the number used will be derived from the core count of the environment. This cannot be combined with `executor`. :type max_workers: Optional[int] .. admonition:: Example: .. literalinclude:: ../samples/sync_samples/sample_code_servicebus.py :start-after: [START auto_lock_renew_message_sync] :end-before: [END auto_lock_renew_message_sync] :language: python :dedent: 4 :caption: Automatically renew a message lock .. literalinclude:: ../samples/sync_samples/sample_code_servicebus.py :start-after: [START auto_lock_renew_session_sync] :end-before: [END auto_lock_renew_session_sync] :language: python :dedent: 4 :caption: Automatically renew a session lock """ def __init__( self, max_lock_renewal_duration=300, on_lock_renew_failure=None, executor=None, max_workers=None, ): # type: (float, Optional[LockRenewFailureCallback], Optional[ThreadPoolExecutor], Optional[int]) -> None """Auto renew locks for messages and sessions using a background thread pool. :param max_lock_renewal_duration: A time in seconds that locks registered to this renewer should be maintained for. Default value is 300 (5 minutes). :type max_lock_renewal_duration: float :param on_lock_renew_failure: A callback may be specified to be called when the lock is lost on the renewable that is being registered. Default value is None (no callback). :type on_lock_renew_failure: Optional[LockRenewFailureCallback] :param executor: A user-specified thread pool. This cannot be combined with setting `max_workers`. :type executor: Optional[~concurrent.futures.ThreadPoolExecutor] :param max_workers: Specify the maximum workers in the thread pool. If not specified the number used will be derived from the core count of the environment. This cannot be combined with `executor`. :type max_workers: Optional[int] """ self._executor = executor or ThreadPoolExecutor(max_workers=max_workers) self._shutdown = threading.Event() self._sleep_time = 1 self._renew_period = 10 self._max_lock_renewal_duration = max_lock_renewal_duration self._on_lock_renew_failure = on_lock_renew_failure def __enter__(self): if self._shutdown.is_set(): raise ServiceBusError( "The AutoLockRenewer has already been shutdown. Please create a new instance for" " auto lock renewing." ) return self def __exit__(self, *args): self.close() def _renewable(self, renewable): # pylint: disable=protected-access if self._shutdown.is_set(): return False if hasattr(renewable, "_settled") and renewable._settled: return False if not renewable._receiver._running: return False if renewable._lock_expired: return False return True def _auto_lock_renew( self, receiver, renewable, starttime, max_lock_renewal_duration, on_lock_renew_failure=None, renew_period_override=None, ): # pylint: disable=protected-access _log.debug( "Running lock auto-renew thread for %r seconds", max_lock_renewal_duration ) error = None clean_shutdown = False # Only trigger the on_lock_renew_failure if halting was not expected (shutdown, etc) renew_period = renew_period_override or self._renew_period try: while self._renewable(renewable): if (utc_now() - starttime) >= datetime.timedelta( seconds=max_lock_renewal_duration ): _log.debug( "Reached max auto lock renew duration - letting lock expire." ) raise AutoLockRenewTimeout( "Auto-renew period ({} seconds) elapsed.".format( max_lock_renewal_duration ) ) if (renewable.locked_until_utc - utc_now()) <= datetime.timedelta( seconds=renew_period ): _log.debug( "%r seconds or less until lock expires - auto renewing.", renew_period, ) try: # Renewable is a session renewable.renew_lock() # type: ignore except AttributeError: # Renewable is a message receiver.renew_message_lock(renewable) # type: ignore time.sleep(self._sleep_time) clean_shutdown = not renewable._lock_expired except AutoLockRenewTimeout as e: error = e renewable.auto_renew_error = e clean_shutdown = not renewable._lock_expired except Exception as e: # pylint: disable=broad-except _log.debug("Failed to auto-renew lock: %r. Closing thread.", e) error = AutoLockRenewFailed("Failed to auto-renew lock", error=e) renewable.auto_renew_error = error finally: if on_lock_renew_failure and not clean_shutdown: on_lock_renew_failure(renewable, error)
[docs] def register( self, receiver, renewable, max_lock_renewal_duration=None, on_lock_renew_failure=None, ): # type: (ServiceBusReceiver, Renewable, Optional[float], Optional[LockRenewFailureCallback]) -> None """Register a renewable entity for automatic lock renewal. :param receiver: The ServiceBusReceiver instance that is associated with the message or the session to be auto-lock-renewed. :type receiver: ~azure.servicebus.ServiceBusReceiver :param renewable: A locked entity that needs to be renewed. :type renewable: Union[~azure.servicebus.ServiceBusReceivedMessage, ~azure.servicebus.ServiceBusSession] :param max_lock_renewal_duration: A time in seconds that the lock should be maintained for. Default value is 300 (5 minutes). :type max_lock_renewal_duration: Optional[float] :param on_lock_renew_failure: A callback may be specified to be called when the lock is lost on the renewable that is being registered. Default value is None (no callback). :type on_lock_renew_failure: Optional[LockRenewFailureCallback] :rtype: None """ if not isinstance(renewable, (ServiceBusReceivedMessage, ServiceBusSession)): raise TypeError( "AutoLockRenewer only supports registration of types " "azure.servicebus.ServiceBusReceivedMessage (via a receiver's receive methods) and " "azure.servicebus.ServiceBusSession (via a session receiver's property receiver.session)." ) if self._shutdown.is_set(): raise ServiceBusError( "The AutoLockRenewer has already been shutdown. Please create a new instance for" " auto lock renewing." ) if renewable.locked_until_utc is None: raise ValueError( "Only azure.servicebus.ServiceBusReceivedMessage objects in PEEK_LOCK receive mode may" "be lock-renewed. (E.g. only messages received via receive() or the receiver iterator," "not using RECEIVE_AND_DELETE receive mode, and not returned from Peek)" ) starttime = get_renewable_start_time(renewable) # This is a heuristic to compensate if it appears the user has a lock duration less than our base renew period time_until_expiry = get_renewable_lock_duration(renewable) renew_period_override = None # Default is 10 seconds, but let's leave ourselves a small margin of error because clock skew is a real problem if time_until_expiry <= datetime.timedelta( seconds=self._renew_period + SHORT_RENEW_OFFSET ): renew_period_override = ( time_until_expiry.seconds * SHORT_RENEW_SCALING_FACTOR ) self._executor.submit( self._auto_lock_renew, receiver, renewable, starttime, max_lock_renewal_duration or self._max_lock_renewal_duration, on_lock_renew_failure or self._on_lock_renew_failure, renew_period_override, )
[docs] def close(self, wait=True): """Cease autorenewal by shutting down the thread pool to clean up any remaining lock renewal threads. :param wait: Whether to block until thread pool has shutdown. Default is `True`. :type wait: bool :rtype: None """ self._shutdown.set() self._executor.shutdown(wait=wait)